Connecting to TSP2012 by Tektronix in Python
Instrument Card
The TPS2000 Series easily addresses the unique challenges that plague industrial power designers and technicians. You regularly confront high voltages and currents, and must often make potentially hazardous floating measurements. With the TPS2000 Seriesโ power bundle (TPS2PBND), which includes the P5120 passive, high-voltage probes and TPS2PWR1 power measurement and analysis software, you can use a single instrument to make a broad range of measurements.
Easily evaluate these high voltages and currents, or debug power electronics control circuits, with differential voltages up to 600 VRMS CAT II (or 300 VRMS CAT III) floating. Accurately measure three-phase power and circuits with different low levels or ground references.
Quickly perform a broad range of power-specific measurements, such as switching loss, harmonic distortion measurements to the 50th harmonic, and dv/dt and di/dt cursor measurements.
Device Specification: here
Manufacturer card: TEKTRONIX
Tektronix, Inc., historically widely known asย Tek, is an American company best known for manufacturing test and measurement devices such asย oscilloscopes,ย logic analyzers, and video and mobile test protocol equipment.
- Headquarters: USA
- Yearly Revenue (millions, USD): 5800
- Vendor Website: here
Demo: Measure signal width and phase with a Tektronix oscilloscope
Connect to the TSP2012 in Python
Read our guide for turning Python scripts into Flojoy nodes.
OSCILLOSCOPES > TEKTRONIX
๐ ADVANCED MEASUREMENTS MDO3XXX
Extract waveform measurements from an MDO3xxx oscilloscope.
๐ CONNECTION MDO3XXX
Connect Flojoy to a MDO3XXX oscilloscope.
๐ EXTRACT TRACE MDO3XXX
Extract a trace from an MDO3xxx oscilloscope.
๐ MEASUREMENTS MDO3XXX
Extract waveform measurements from an MDO3XXX oscilloscope.
๐ MEASURE PHASE MDO3XXX
Measure the phase between two channels on an MDO3XXX oscilloscope.
๐ TERMINATION MDO3XXX
The TERMINATION_MDO3XXX block sets the termination ohms (or queries it).
๐ TRIGGER CHANNEL MDO3XXX
Set the triggering channel of a MDO3XXX oscilloscope (or query it).
๐ TRIGGER LEVEL MDO3XXX
Set the trigger voltage of a MDO3XXX oscilloscope (or queries it).
๐ TRIGGER SETTINGS MDO3XXX
Sets advanced trigger settings for an MDO3XXX oscilloscope.
๐ AFG MSO2X
Set the MSO2XX Function Generator settings.
๐ CHANNEL DISPLAY MSO2X
Set the MSO2XX channels on (1) or off (0).
๐ CONNECT MSO2X
Open a VISA connection to an MSO2X Tektronix oscilloscope.
๐ DECODE I2C MSO2X
Creates a bus decode for decoding I2C.
๐ DIGITAL CHANNELS MSO2X
Set the digital MSO2XX channels on (1) or off (0).
๐ EDGE TRIGGER MSO2X
Set the MSO2XX edge trigger settings.
๐ HORIZONTAL POSITION MSO2X
Set the MSO2X oscilloscope horizontal position or delay.
๐ HORIZONTAL SCALE MSO2X
Set the MSO2X oscilloscope viewport.
๐ I2C TRIGGER MSO2X
Set the MSO2XX I2C trigger settings.
๐ MEASUREMENT MSO2X
Measure one of the waveforms for the MSO2X.
๐ PROBE ATTENUATION MSO2X
Set the MSO2XX probe attenuation for specific channel.
๐ QUERY CURVE MSO2X
Returns the curve query on a MSO2X oscilloscope, in voltage vs time.
๐ SCREENSHOT MSO2X
Save a screenshot from a Tektronix MSO oscilloscope.
๐ SETUP FILE MSO2X
Saves or recalls a instrument setup file (.set).
๐ SINGLE TRIGGER MSO2X
Sets the scope into single trigger mode.
๐ VERTICAL POSITION MSO2X
Set the MSO2XX oscilloscope vertical offset for the specified channel.
๐ VERTICAL SCALE MSO2X
Set the MSO2XX oscilloscope viewport.
PROTOCOLS > SCPI
Here is an example Python script that uses Qcodes to connect to a TPS2012 Oscilloscope:
Note: Replace 'TCPIP0::192.168.1.1::INSTR'
with the actual address of your TPS2012 Oscilloscope.